XSA800 系列頻譜分析儀
+-160 dBm 顯示平均雜訊電平 (DANL)
+相位雜訊:-80 dBc/Hz(@1GHz)和偏移(10 kHz)
+總幅度精度 <0.7 dB
+1 Hz 最小解析度頻寬 (RBW)
+EMI預一致性測試功能(免費),EMC測試軟體(可選)
+可選追蹤產生器(購買后可升級為TG)
+瀑布圖圖形、調製信號品質分析、
音訊解調等。多個通用和擴展
測試函數。
+標準通過/失敗現場測試和警報功能
+採用全數位中頻技術
+多種介面:USB 主機、USB 設備、LAN、
耳機介面,HDMI
+9 英寸 LCD,高解析度 1280×800 像素
Frequency |
||||||
Frequency Range |
XSA805 |
9 kHz to 500 MHz |
||||
XSA810 |
9 kHz to 1 GHz |
|||||
XSA815 |
9 kHz to 1.5 GHz |
|||||
Frequency Resolution |
1 Hz |
|||||
Reference frequency aging rate |
< 1 ppm/year |
|||||
Frequency Span |
||||||
Span Range |
0 Hz, 100 Hz to max frequency of instrument |
|||||
Span Uncertainty |
± span / (sweep points-1) |
|||||
SSB Phase Noise(20℃ to 30℃, fc = 500 MHz) |
||||||
Carrier Offset |
10 kHz |
< -80 dBc/Hz |
||||
100 kHz |
< -100 dBc/Hz |
|||||
1 MHz |
< -115 dBc/Hz |
|||||
Bandwidth |
||||||
Resolution Bandwidth(-3 dB) |
1 Hz to 1 MHz, in 1-3-5-10 sequence |
|||||
Resolution Bandwidth (-6 dB) (EMI) |
200 Hz, 9 kHz, 120 kHz, 1 MHz |
|||||
RBW Accuracy |
< 5% typical |
|||||
Resolution Filter Shape Factor (60 dB : 3 dB) |
< 5 typical |
|||||
Video |
10 Hz to 1 MHz, in 1-3-5-10 sequence |
|||||
Amplitude and level |
||||||
Amplitude measurement range |
DANL to +10 dBm, 100 kHz to 10 MHz, Preamp Off |
|||||
Reference Level |
-80 dBm to +30 dBm, 0.01 dB by step |
|||||
Preamp |
20 dB, nominal, 100 kHz to 1.5 GHz |
|||||
Input Attenuator |
0 to 40 dB, 1 dB by step |
|||||
Display Average Noise Level (Input attenuation = 0 dB, RBW = VBW = 100 Hz, sample detector, trace average ≥ 50, 20℃ to 30℃, input impedance = 50 Ω) |
||||||
Preamp Off |
9 kHz to 1 MHz |
-95 dBm (Typical), <-88 dBm |
||||
1 MHz to 500 MHz |
-140 dBm (Typical), <-130dBm |
|||||
XSA810 |
500 MHz to 1 GHz |
|||||
XSA815 |
500 MHz to 1.5 GHz |
-138 dBm (Typical), <-128 dBm |
||||
Preamp On |
100 kHz to 1 MHz |
-135 dBm (Typical), <-128 dBm |
||||
1 MHz to 500 MHz |
-160 dBm (Typical), <-150 dBm |
|||||
XSA810 |
500 MHz to 1 GHz |
|||||
XSA815 |
500 MHz to 1.5 GHz |
-158 dBm (Typical), <-148 dBm |
||||
Level Display |
||||||
Trace detectors |
positive-peak, negative-peak, normal, sample, RMS, voltage average, quasi-peak |
|||||
Trace functions |
clear write, max hold, min hold, average, view, blank, trace math |
|||||
Units of level axis |
dBm, dBμW, dBpW, dBmV, dBμV, W, V |
|||||
Frequency response |
||||||
Preamp Off |
<0.7 dB |
|||||
Preamp On |
<1.0 dB |
|||||
Difference and Accuracy |
||||||
Uncertainty |
fc = 50 MHz, peak detector, preamplifier off, attenuation = 10 dB, input signal level = -10 dBm, 20℃ to 30℃ |
|||||
< 0.4 dB |
||||||
Level Measurement Uncertainty |
||||||
Level measurement uncertainty |
95% confidence level, S/N > 20 dB, RBW = VBW = 1 kHz, preamplifier off, attenuation = 10 dB, -50 dBm < input level ≤ 0 dBm, fc > 10 MHz, 20℃ to 30℃ |
|||||
< 0.7 dB |
||||||
Tracking Generator (optional) |
||||||
Frequency Range |
XSA805 |
100 kHz to 500 MHz |
||||
XSA810 |
100 kHz to 1 GHz |
|||||
XSA815 |
100 kHz to 1.5 GHz |
|||||
Output power |
-40 dBm to 0 dBm |
|||||
Output level resolution |
1 dB |
|||||
Output flatness |
Relative to 50 MHz |
|||||
± 3 dB |
||||||
Tracking generator spurious |
Harmonic spurious |
-30 dBc (Tracking generator output power -10 dBm) |
||||
Non-harmonic spurious |
-40 dBc (Tracking generator output power -10 dBm) |
|||||
Tracking generator to input terminal isolation |
-60 dB (Tracking generator output power 0 dBm) |
|||||
Interface |
||||||
USB Host, USB Device, LAN, earphone interface, HDMI |
||||||
Display |
||||||
9-inch TFT LCD, 1280 x 800 pixels |
||||||
Appearance |
||||||
Dimensions |
375 mm (W) × 185 mm (H) × 120 mm (D) |
|||||
Weight |
Approx. 3.7 kg (main device) |